PS 400 Cable ducts

Intelligent solution for cables.

Cables are necessary – but are not an optical beauty. Requests gave birth to the idea of having an independent program exclusively for cable ducts. Problem: An outlet here, electricity needed there and a door is between the two. The solution: PS 400 Cable duct type 1 that makes space for standard device cables, telephone or speaker cables in a cable shaft. At the same time, it is so small that it discretely disappears under the door. The especially flat cable duct type 2 also makes larger amounts of cables (up to 8 standard device cables) disappear into laminate or parquet floors. The bars on the bottom side reach over the cable guides for the base – thus, there are closed chambers in which the cables are securely protected. PS 400 Cable ducts are optimal for the installation of flooring thicknesses between 7–18 mm.

PS 400 Kabelkanal

PS 400 Cable duct no. 432, Type 1

> Aluminium.

> For covering thicknesses 7-18 mm.

> For connections of equal height or for the compensation of differences in level up to 3 mm.

> 1 cable duct with a cross-section of 100-200 mm2.

> Inclusive fixing material.

PS 400 Profile System

Color SB Article Number EAN-Code Length (cm)
gold 432 23 10 270 4012406 00720 6 270
gold SB 432 23 10 090 4012406 00721 3 90
sahara 432 23 13 270 4012406 00722 0 270
sahara SB 432 23 13 090 4012406 00723 7 90
silver 432 23 11 270 4012406 00724 4 270
silver SB 432 23 11 090 4012406 00725 1 90
havanna 432 23 14 270 4012406 00726 8 270
havanna SB 432 23 14 090 4012406 00727 5 90
Edelstahl-Optik poliert 432 23 09 270 4012406 00718 3 270
Edelstahl-Optik poliert SB 432 23 09 090 4012406 00719 0 90

PS 400 Cable duct no. 430, Type 2

> Aluminium.

> For covering thicknesses 7-18 mm.

> For connections of equal height or for the compensation of differences in level up to 6 mm.

> 2 cable ducts with a cross-section of 200-440 mm2.

> Inclusive fixing material.

PS 400 Profile System

Color Article Number EAN-Code Length (cm)
gold 430 23 10 270 4012406 00714 5 270
sahara 430 23 13 270 4012406 00715 2 270
silver 430 23 11 270 4012406 00716 9 270
havanna 430 23 14 270 4012406 00717 6 270
Edelstahl-Optik poliert 430 23 09 270 4012406 00713 8 270

Function

PS 400 Cable ducts:
For floor coverings 7–18 mm

Your benefits:

  • Concealed laying of cables in parquet / laminate floors.
  • Subsequent laying possible.
  • Suitable for floor thicknesses between 7–18 mm.
  • Minimal stocks required.
  • Automatic adjustment to height and inclination.
  • Optimal frictional connection by traction.
  • Simple, fast, and reliable installation.

Profilarten

Montagearten

Zertifikate

Übergangsprofil

Schrauben


Installation

Product information:

Fast access.

PS 400 Cable ducts are perfect to combine with aluminium – clip baseboards no. 350. With this, you can conceal cable at every point in the floor or wall area. The cables are accessible at all times.

Quick method for perfect installation:

(1) Fitting of base section

Screw or glue the base section with the subsurface.
We recommend bolting down.

Screwing:

Align the base section on the subsurface considering an extension joint. Drill the holes for the anchors through the screw holes of the base section by means of a 5 mm drill. The anchors can be placed into the floor directly through the drill holes of the bottom section.

Gluing:

Use a two-package system or glue with especially high adhesiveness, e.g. Kleiberit. Have the glue completely cured before fixing the top section.

(2) Laying protective conductors

If live wires are laid in the cable duct, the section must be earthed with a protective conductor by a qualified electrician. If more than one duct is laid, the base sections must be connected with a cable bridge. The top section is in contact with the earthed base section through the attachment using drilling screws. No protective conductor is required for data, network or loudspeaker cables.

(3) Inserting cables

The cables to be laid can now be inserted into the cable duct of the base section. If more than one cable is laid per duct, they have to be bundled at a spacing of 30 cm. The cable must not be twisted and must lie smoothly within the cable duct. A suitable insulation tape can be used for bundling.

(4) Attaching the top section

The guides of the top section surround the sides of the cable duct and the base section. The top section automatically matches the floor covering in height and inclination. When attaching the top section, it must be ensured that no cable is located between the top section and the base section.

(5) Select drilling screws, fixing of top section

The correct length of the screw can be determined by putting the screw into the screw hole. The length is correct, if the screw projects 4 - 8 mm. To fix the top section, please use an accumulator screwdriver with bit PH-1. Under slight pressure and with average torque, the drilling screws drive a thread into the screw base of the base section.

Dismounting:

The screw can be unscrewed and screwed in again.

Carl Prinz GmbH & Co. KG

Jakobstr. 8
D-47574 Goch

+49 (0) 28 23. 97 03-0
+49 (0) 28 23. 8 04 95

> Send an e-mail

Interview with Katharina Prinz

The managing director of Carl Prinz GmbH und Co. KG offers an insight into her daily life as an entrepreneur.

> Read interview

The Prinz power package

PROFI-TEC excels with its perfect appearance without any screw holes and easily stands up to pressure loads of up to 1.5 tonnes.

> Get to know PROFI-TEC

The Prinz original for wooden floors

The D.O.S. system is suitable for laying laminate and parquet floors with thicknesses of up to 23.5 mm.

> Get to know D.O.S. for wooden floors

The Prinz original for fitted carpets

The D.O.S. System is ideally suited for textile and elastic floor coverings.

> Get to know D.O.S. for fitted carpets