Specifications compared | ||
---|---|---|
Impact noise reduction [IS] | 20 dB(A) | |
Footfall sound improvement [RWS] | 23 % | |
Thermal resistance [R] | 0,14 m² K/W | |
Suitable for underfloor heating | no | |
Moisture protection [SD] | ||
Compensation of unevennesses [PC] | 4 mm | |
Load-bearing capacity [CS] | 90 kPa | |
Durability [DL] | 250,000 cycles | |
Low-friction surface [CC] | ||
Diffusion potential [RLB] | 1,600 mm | |
Anti-slip surface |
Item number | Strength | Width | Length | Density |
---|---|---|---|---|
880 12 00 000 | 5 mm | 59 cm | 79 cm | 40 kg/m³ |
Specifications compared | ||
---|---|---|
Impact noise reduction [IS] | 16 dB(A) | |
Footfall sound improvement [RWS] | 22 % | |
Thermal resistance [R] | 0,01 m² K/W | |
Suitable for underfloor heating | yes | |
Moisture protection [SD] | ||
Compensation of unevennesses [PC] | 0.69 mm | |
Load-bearing capacity [CS] | 260 kPa | |
Durability [DL] | 2.000.000 cycles | |
Low-friction surface [CC] | ||
Diffusion potential [RLB] | ||
Anti-slip surface |
Item number | Strength | Width | Length | Density |
---|---|---|---|---|
880 18 00 000 | 1,5 mm | 100 cm | 10 m | 1,5 kg/m² |
Specifications compared | ||
---|---|---|
Impact noise reduction [IS] | 16 dB(A) | |
Footfall sound improvement [RWS] | 22 % | |
Thermal resistance [R] | 0,01 m² K/W | |
Suitable for underfloor heating | yes | |
Moisture protection [SD] | SD > 75 m | |
Compensation of unevennesses [PC] | 0.69 mm | |
Load-bearing capacity [CS] | 260 kPa | |
Durability [DL] | 2.000.000 cycles | |
Low-friction surface [CC] | ||
Diffusion potential [RLB] | ||
Anti-slip surface |
Item number | Strength | Width | Length | Density |
---|---|---|---|---|
880 19 00 000 | 1,5 mm | 100 cm | 10 m | 1,5 kg/m² |
Specifications compared | ||
---|---|---|
Impact noise reduction [IS] | 18 dB(A) | |
Footfall sound improvement [RWS] | 24 % | |
Thermal resistance [R] | 0,01 m² K/W | |
Suitable for underfloor heating | yes | |
Moisture protection [SD] | SD > 75 m | |
Compensation of unevennesses [PC] | 0.92 mm | |
Load-bearing capacity [CS] | 220 kPa | |
Durability [DL] | 2.000.000 cycles | |
Low-friction surface [CC] | ||
Diffusion potential [RLB] | ||
Anti-slip surface |
Item number | Strength | Width | Length | Density |
---|---|---|---|---|
880 26 00 000 | 2 mm | 100 cm | 8,5 m | 1,5 kg/m² |
Specifications compared | ||
---|---|---|
Impact noise reduction [IS] | 18 dB(A) | |
Footfall sound improvement [RWS] | 27 % | |
Thermal resistance [R] | 0,01 m² K/W | |
Suitable for underfloor heating | yes | |
Moisture protection [SD] | SD > 75 m | |
Compensation of unevennesses [PC] | 1.35 mm | |
Load-bearing capacity [CS] | 170 kPa | |
Durability [DL] | 2.000.000 cycles | |
Low-friction surface [CC] | ||
Diffusion potential [RLB] | ||
Anti-slip surface |
Item number | Strength | Width | Length | Density |
---|---|---|---|---|
880 22 00 000 | 2,6 mm | 100 cm | 6 m | 2 kg/m² |